This standard is issued under the fixed designation D ; the number 1 This practice is under the jurisdiction of ASTM Committee D01 on Paint and. Related. In nearly the same timeframe, the version of ASTM D, “Standard Practice for Nondestructive Measurement of Dry Film Thickness of. ASTM D describes three operational steps that must be performed prior to coating thickness measurement to help assure the reliability of.
Author: | Vugul Arashigis |
Country: | Pacific Islands |
Language: | English (Spanish) |
Genre: | Career |
Published (Last): | 17 March 2016 |
Pages: | 109 |
PDF File Size: | 14.54 Mb |
ePub File Size: | 6.43 Mb |
ISBN: | 795-6-12969-464-7 |
Downloads: | 82472 |
Price: | Free* [*Free Regsitration Required] |
Uploader: | Mir |
This method is used when the largest dimension of the unit is less than 10 feet. For decades, the industry was cautioned about taking coating thickness measurements within 1 inch of an edge, let alone on an edge.
This practice does not address the use of ultrasonic coating thickness gages. The BMR is the effect of substrate roughness on a coating thickness gage. The standard has been updated on multiple occasions. Provisions for measuring on soft or tacky coatings are described in. Kaunteya, Thank you for your question. Special tensioned ring shims are also available.
Measuring Coating Thickness According To SSPC-PA 2 – Update 2015
All references to the frequency of measurements were removed from the ASTM standard. The user of this equipment must be knowledgeable in the proper operation of these devices, including methods for verifying the accuracy of the equipment prior to, during and after use as well as measurement procedures.
Even ashm a project speci? If so which is the correct surface for calibrating? If a large number of measurements are being obtained, the user may opt to verify gage accuracy during measurement acquisition for example, hourly. Less force is required to remove the magnet from a thick coating, while more force is required to remove the magnet from a thinner one.
Measuring Dry Film Coating Thickness According to SSPC-PA 2
Provisions for measuring on soft or tacky coatings are described in 5. Updates to SSPC and other industry-provided inspector training and certification courses and the associated instructor education will be critical to fully understanding and effectively communicating the requirements of this highly regarded industry standard. This procedure also verifies that the probe configuration will accommodate the edge configuration before acquiring coating thickness data.
Courtesy of SSPC The number of areas that must be measured for coating thickness varies, depending on the size of the coated area. Historical Version s – view previous versions of standard. For example, the thickness may need to be measured in each 9 m2 ft2 area in accordance with 8.
They are typically regarded to be faster, more accurate, and easier to use. Leave this field empty.
By continuing to use our site, you accept our use of cookies To learn more, click Read More to view our Privacy and Cookies Policy. Place the gage probe on a certified coated standard and adjust the gage as necessary. The number of spot measurements along the edge will vary, depending on the total length of the coated edge.
The average of the acceptable gage readings is the spot measurement. A one-year calibration interval is a typical starting point suggested by gage manufacturers. This too can create a potential conundrum — determining the correct abrasive mix that will generate the correct combination of height and density.
The average of the three acceptable gage readings is the spot measurement. If the user elects to use shims to verify the accuracy of Type 1 gages, the shim s representing the intended range of use should be placed onto a smooth steel surface zero plateand a measurement taken.
Place a measured shim comes with the gage onto the prepared, uncoated metal surface to be coated; Adjust the gage reading to match the thickness of the shim. D0791 measured distance is displayed as coating thickness by the gages. Isolation of nonconforming areas required measurement of each square foot area painted during the work shift.
Measuring Coating Thickness According To SSPC-PA2 – Update KTA University
There are three categories of coated area: Certified Standards Definition Added. Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.
Adjustment to correct for roughness via BMR or shims certified or measured shims. Communicating the new requirements of this standard asrm the industry is challenging but essential. They are typically regarded to be faster, more accurate and easier to use. Pipe sections loaded onto a cart or rack can be considered a complete unit Fig. For a given measurement direction or unit measurement, any compliant area or unit atm a non-compliant area or unit is designated as suspect, and as such is subject to re-inspection after corrective measures are performed.